FEATURES Next-Generation Upgrade of ADM1021 On-Chip and Remote Temperature Sensing Offset Registers for System Calibration 1 C Accuracy and Resolution on Local Channel 0.125 C Resolution/1 C Accuracy on Remote Channel Programmable Over/Under Temperature Limits Programmable Conversion Rate Supports System Management Bus (SMBus) Alert 2-Wire SMBus Serial Interface 200 A Max Operating Current (0.25 Conversions/ Seconds) 1 A Standby Current 3 V to 5.5 V Supply Small 16-Lead QSOP Package APPLICATIONS Desktop Computers Notebook Computers Smart Batteries Industrial Controllers Telecomms Equipment Instrumentation
ACPI Compliant High Accuracy Microprocessor System Temperature Monitor ADM1023*
PRODUCT DESCRIPTION
The ADM1023 is a 2-channel digital thermometer and under/over temperature alarm, intended for use in personal computers and other systems requiring thermal monitoring and management. Optimized for the Pentium(R) III; the higher accuracy offered allows systems designers to safely reduce temperature guard banding and increase system performance. The device can measure the temperature of a microprocessor using a diode-connected PNP transistor, which may be provided on-chip in the case of the Pentium III or similar processors or can be a low-cost discrete NPN/PNP device such as the 2N3904/2N3906. A novel measurement technique cancels out the absolute value of the transistor's base emitter voltage, so that no calibration is required. The second measurement channel measures the output of an on-chip temperature sensor to monitor the temperature of the device and its environment. The ADM1023 communicates over a 2-wire serial interface compatible with SMBus standards. Under and over temperature limits can be programmed into the device over the serial bus, and an ALERT output signals when the on-chip or remote temperature is out of range. This output can be used as an interrupt, or as an SMBus alert.
FUNCTIONAL BLOCK DIAGRAM
ADDRESS POINTER REGISTER ONE-SHOT REGISTER CONVERSION RATE REGISTER ON-CHIP TEMPERATURE SENSOR OFFSET REGISTERS LOCAL TEMPERATURE VALUE REGISTER LOCAL TEMPERATURE LOW-LIMIT COMPARATOR LOCAL TEMPERATURE HIGH-LIMIT COMPARATOR REMOTE TEMPERATURE LOW-LIMIT COMPARATOR REMOTE TEMPERATURE HIGH-LIMIT COMPARATOR LOCAL TEMPERATURE LOW-LIMIT REGISTER LOCAL TEMPERATURE HIGH-LIMIT REGISTER REMOTE TEMPERATURE LOW-LIMIT REGISTERS REMOTE TEMPERATURE HIGH-LIMIT REGISTERS CONFIGURATION REGISTER EXTERNAL DIODE OPEN-CIRCUIT STATUS REGISTER INTERRUPT MASKING STBY ALERT
D+ D-
ANALOG MUX
A-TO-D CONVERTER BUSY RUN/STANDBY REMOTE TEMPERATURE VALUE REGISTERS
ADM1023
SMBUS INTERFACE
NC
VDD
NC
GND
GND
NC
NC
NC
NC = NO CONNECT
SDATA
SCLK
ADD0
ADD1
*Patents pending
REV. F
Information furnished by Analog Devices is believed to be accurate and reliable. However, no responsibility is assumed by Analog Devices for its use, nor for any infringements of patents or other rights of third parties that may result from its use. No license is granted by implication or otherwise under any patent or patent rights of Analog Devices. Trademarks and registered trademarks are the property of their respective companies.
One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106, U.S.A. Tel: 781/329-4700 www.analog.com Fax: 781/326-8703 (c) 2003 Analog Devices, Inc. All rights reserved.
ADM1023-SPECIFICATIONS (T = T
A
MIN
to TMAX1, VDD = 3.0 V to 3.6 V, unless otherwise noted.)
Max Unit C C C C C C C V V mV V mV mA mA mA mA ms mA mA V mA V 0.8 V mA mA mA pF kHz ms ns ns ns ns ns ms ms ms mA Test Conditions/Comments Guaranteed No Missed Codes Guaranteed No Missed Codes TA = 60C to 100C TA = 0C to 120C TA, TD = 60C to 100C (Note 2) TA, TD = 0C to 120C (Note 2) TA = 60C to 100C Note 3 VDD Input, Disables ADC, Rising Edge VDD, Falling Edge (Note 4) VDD = 3.3 V, No SMBus Activity SCLK at 10 kHz 0.25 Conversions/Sec Rate 2 Conversions/Sec Rate From Stop Bit to Conversion Complete (Both Channels) D+ Forced to D- + 0.65 V High Level (Note 4) Low Level (Note 4) Momentary at Power-On Reset (See Figure 1) VDD = 3 V to 5.5 V VDD = 3 V to 5.5 V SDATA Forced to 0.6 V ALERT Forced to 0.4 V
Parameter POWER SUPPLY AND ADC Temperature Resolution, Local Sensor Temperature Resolution, Remote Sensor Temperature Error, Local Sensor Temperature Error, Remote Sensor Relative Accuracy Supply Voltage Range Undervoltage Lockout Threshold Undervoltage Lockout Hysteresis Power-On Reset Threshold POR Threshold Hysteresis Standby Supply Current Average Operating Supply Current Autoconvert Mode, Averaged Over 4 Sec Conversion Time
Min 1 0.125 -1.5 -3 -1 -3 3 2.55 0.9
Typ
0.5 1
65
2.7 25 1.7 50 1 4 130 225 115
+1.5 +3 +1 +3 0.25 3.6 2.8 2.2 5 200 330 170
Remote Sensor Source Current D-Source Voltage Address Pin Bias Current (ADD0, ADD1) SMBus INTERFACE Logic Input High Voltage, VIH STBY, SCLK, SDATA Logic Input Low Voltage, VIL STBY, SCLK, SDATA SMBus Output Low Sink Current ALERT Output Low Sink Current Logic Input Current, IIH, IIL SMBus Input Capacitance, SCLK, SDATA SMBus Clock Frequency SMBus Clock Low Time, tLOW SMBus Clock High Time, tHIGH SMBus Start Condition Setup Time, tSU:STA SMBus Start Condition Hold Time, tHD:STA SMBus Stop Condition Setup Time, tSU:STO SMBus Data Valid to SCLK Rising Edge Time, tSU:DAT SMBus Data Hold Time, tHD:DAT SMBus Bus Free Time, tBUF SCLK Falling Edge to SDATA Valid Time, tVD, DAT SMBus Leakage Current
120 7
205 12 0.7 50
300 16
2.2
6 1 -1 5
+1 100
4.7 4 4.7 4 4 250 0 4.7 1 5
tLOW Between 10% Points tHIGH Between 90% Points Time from 10% of SDATA to 90% of SCLK Time from 90% of SCLK to 10% of SDATA Time for 10% or 90% of SDATA to 10% of SCLK Between Start/Stop Condition Master Clocking in Data VDD = 0 V
NOTES 1 TMAX = 120C, TMIN = 0C. 2 TD is temperature of remote thermal diode; T A, TD = 60C to 100C. 3 Operation at V DD = 5 V guaranteed by design, not production tested. 4 Guaranteed by design, not production tested. Specifications subject to change without notice.
-2-
REV. F
ADM1023
ABSOLUTE MAXIMUM RATINGS* PIN CONFIGURATION
Positive Supply Voltage (VDD) to GND . . . . . . -0.3 V to +6 V D+, ADD0, ADD1 . . . . . . . . . . . . . . . -0.3 V to VDD + 0.3 V D- to GND . . . . . . . . . . . . . . . . . . . . . . . . . . -0.3 V to +0.6 V SCLK, SDATA, ALERT, STBY . . . . . . . . . . . -0.3 V to +6 V Input Current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 mA Input Current, D- . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 mA ESD Rating, all pins (Human Body Model) . . . . . . . . 2000 V Continuous Power Dissipation Up to 70C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 650 mW Derating Above 70C . . . . . . . . . . . . . . . . . . . . . 6.7 mW/C Operating Temperature Range . . . . . . . . . . -55C to +125C Maximum Junction Temperature (TJ MAX) . . . . . . . . . . 150C Storage Temperature Range . . . . . . . . . . . . -65C to +150C Lead Temperature (Soldering 10 sec) . . . . . . . . . . . . . . 300C IR Reflow Peak Temperature . . . . . . . . . . . . . . . . . . . . . 220C
*Stresses above those listed under Absolute Maximum Ratings may cause permanent damage to the device. This is a stress rating only; functional operation of the device at these or any other conditions above those indicated in the operational section of this specification is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability.
NC 1 VDD 2 D+ 3
16 15 14
NC STBY SCLK
D- 4 ADM1023 13 NC TOP VIEW NC 5 (Not to Scale) 12 SDATA ADD1 6 GND 7 GND 8
11 10 9
ALERT ADD0 NC
NC = NO CONNECT
PIN FUNCTION DESCRIPTIONS
Pin No. Mnemonic Description 1, 5, 9, 13, 16 2 3 4 6 NC VDD D+ D- ADD1 GND ADD0 ALERT SDATA SCLK STBY No Connect Positive Supply, 3 V to 5.5 V Positive connection to remote temperature sensor Negative connection to remote temperature sensor Three-state logic input, higher bit of device address Supply 0 V Connection Three-state logic input, lower bit of device address Open-drain logic output used as interrupt or SMBus alert Logic input/output, SMBus serial data. Open-drain output. Logic input, SMBus serial clock Logic input selecting normal operation (high) or standby mode (low)
THERMAL CHARACTERISTICS
16-Lead QSOP Package qJA = 105C/W qJC = 39C/W
ORDERING GUIDE
Model ADM1023ARQ
Temperature Range 0C to 120C
Package Description 16-Lead QSOP
Package Option RQ-16
7, 8 10 11 12 14 15
tHD;STA tLOW
SCL
tR
tF
tHD;STA
SDA
tHD;DAT
tHIGH
tSU;DAT
tSU;STA
tSU;STO
tBUF
P S S P
Figure 1. Diagram for Serial Bus Timing
CAUTION ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily accumulate on the human body and test equipment and can discharge without detection. Although the ADM1023 features proprietary ESD protection circuitry, permanent damage may occur on devices subjected to high energy electrostatic discharges. Therefore, proper ESD precautions are recommended to avoid performance degradation or loss of functionality.
REV. F
-3-
ADM1023-Typical Performance Characteristics
20 15 D+ TO GND
TEMPERATURE ERROR - C
3
TEMPERATURE ERROR - C
10 5 0 -5 -10 D+ TO VDD -15 -20 -25 -30 1 10 LEAKAGE RESISTANCE - M 100
2 UPPER SPEC LEVEL 1
0
-1
LOWER SPEC LEVEL
-2
-3 50
60
70
80 90 100 TEMPERATURE - C
110
120
TPC 1. Temperature Error vs. Resistance from Track to VDD and GND
TPC 4. Temperature Error of ADM1023 vs. Pentium III Temperature
5
14 12
TEMPERATURE ERROR - C
TEMPERATURE ERROR - C
4 250mV p-p REMOTE 3
10 8 6 4 2 0
2 100mV p-p REMOTE
1
0 100
-1
1k
10k 100k 1M FREQUENCY - Hz
10M
100M
2
4
6
8
10 12 14 16 CAPACITANCE - nF
18
20
22
24
TPC 2. Remote Temperature Error vs. Supply Noise Frequency
TPC 5. Temperature Error vs. Capacitance Between D+ and D-
9 100mV p-p 8
70 60
A SUPPLY CURRENT -
TEMPERATURE ERROR - C
7 6 5 4 3 2 1 25mV p-p 0 1 10 100 1k 10k 100k FREQUENCY - Hz 1M 0 10M 100M 1 5 10 25 50 75 100 250 SCLK FREQUENCY - kHz 500 750 1000 10 VDD = 5V 50 40 VDD = 3.3V 30
50mV p-p
20
TPC 3. Temperature Error vs. Common-Mode Noise Frequency
TPC 6. Standby Supply Current vs. SCLK Frequency
-4-
REV. F
ADM1023
4 100 80
TEMPERATURE ERROR - C A SUPPLY CURRENT -
3 10mV p-p 2
60
40
20
1
0
0 100k
-20 1M 10M FREQUENCY - Hz 100M 1G 0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 SUPPLY VOLTAGE - V 4.0 4.5 5.0
TPC 7. Temperature Error vs. Differential-Mode Noise Frequency
550 500 450
A SUPPLY CURRENT -
TPC 9. Standby Supply Current vs. Supply Voltage
125 REMOTE TEMPERATURE 100 TEMPERATURE - C
400 350 300 250 200 3.3 V 150 100 50 0.0625 0.125 5V
75
INT TEMPERATURE
50
25
0 0.25 0.5 1 2 CONVERSION RATE - Hz 4 8 0 1 2 3 4 5 6 TIME - Seconds 7 8 9 10
TPC 8. Operating Supply Current vs. Conversion Rate, VDD = 5 V and 3 V
TPC 10. Response to Thermal Shock
FUNCTIONAL DESCRIPTION
The ADM1023 contains a 2-channel A-to-D converter with special input-signal conditioning to enable operation with remote and on-chip diode temperature sensors. When the ADM1023 is operating normally, the A-to-D converter operates in a free-running mode. The analog input multiplexer alternately selects either the on-chip temperature sensor to measure its local temperature or the remote temperature sensor. These signals are digitized by the ADC and the results are stored in the Local and Remote Temperature Value Registers. Only the 8 most significant bits of the local temperature value are stored as an 8-bit binary word. The remote temperature value is stored as an 11-bit binary word in two registers. The 8 MSBs are stored in the Remote Temperature Value High Byte Register at address 01h. The 3 LSBs are stored, leftjustified, in the Remote Temperature Value High Byte Register at address 10h. Error sources such as PCB track resistance and clock noise can introduce offset errors into measurements on the Remote Channel. To achieve the specified accuracy on this channel, these offsets must be removed, and two Offset Registers are provided for this purpose at addresses 11h and 12h. REV. F
An offset value may automatically be added to or subtracted from the measurement by writing an 11-bit, twos complement value to registers 11h (high byte) and 12h (low byte, left-justified). The offset registers default to zero at power-up and will have no effect if nothing is written to them. The measurement results are compared with Local and Remote, High and Low Temperature Limits, stored in six on-chip Limit Registers. As with the measured value, the local temperature limits are stored as 8-bit values and the remote temperature limits as 11-bit values. Out-of-limit comparisons generate flags that are stored in the status register, and one or more out-of-limit results will cause the ALERT output to pull low. Registers can be programmed, and the device controlled and configured, via the serial System Management Bus. The contents of any register can also be read back via the SMBus. Control and configuration functions consist of: * Switching the device between normal operation and standby mode. * Masking or enabling the ALERT output. * Selecting the conversion rate. -5-
ADM1023
VDD I N I IBIAS
D+ REMOTE SENSING TRANSISTOR C1* D- BIAS DIODE LOW-PASS FILTER fC = 65kHz
VOUT+ TO ADC VOUT-
* CAPACITOR C1 IS OPTIONAL. IT IS ONLY NECESSARY IN NOISY ENVIRONMENTS. C1 = 2.2nF TYPICAL, 3nF MAX.
Figure 2. Input Signal Conditioning
On initial power-up the remote and local temperature values default to -128C. Since the device normally powers up converting, a measure of local and remote temperature is made and these values are then stored before a comparison with the stored limits is made. However, if the part is powered up in standby mode (STBY pin pulled low), no new values are written to the register before a comparison is made. As a result, both RLOW and LLOW are tripped in the Status Register, thus generating an ALERT output. This may be cleared in one of two ways: 1. Change both the local and remote lower limits to -128C and read the status register (which in turn clears the ALERT output). 2. Take the part out of standby and read the status register (which in turn clears the ALERT output). This will work only if the measured values are within the limit values.
MEASUREMENT METHOD
cycles. Signal conditioning and measurement of the internal temperature sensor is performed in a similar manner. Figure 2 shows the input signal conditioning used to measure the output of an external temperature sensor. This figure shows the external sensor as a substrate PNP transistor, provided for temperature monitoring on some microprocessors, but it could equally well be a discrete transistor. If a discrete transistor is used, the collector will not be grounded and should be linked to the base. To prevent ground noise from interfering with the measurement, the more negative terminal of the sensor is not referenced to ground, but is biased above ground by an internal diode at the D- input. If the sensor is operating in a noisy environment, C1 may optionally be added as a noise filter. Its value is typically 2200 pF, but should be no more than 3000 pF. See the section on Layout Considerations for more information on C1.
SOURCES OF ERRORS ON THERMAL TRANSISTOR MEASUREMENT METHOD The Effect of Ideality Factor (n)
A simple method of measuring temperature is to exploit the negative temperature coefficient of a diode, or the base emitter voltage of a transistor, operated at constant current. Thus, the temperature may be obtained from a direct measurement of VBE where,
VBE = nKT (I ) 1n C q IS
(1)
Unfortunately, this technique requires calibration to null out the effect of the absolute value of VBE, which varies from device to device. The technique used in the ADM1023 is to measure the change in VBE when the device is operated at two different collector currents. This is given by: nKT DVBE = 1n ( N ) q where: K is Boltzmann's constant q is charge on the electron (1.6 10-19 Coulombs) T is absolute temperature in Kelvins N is ratio of the two collector currents n is the ideality factor of the thermal diode (TD)
The effects of ideality factor (n) and beta (b) of the temperature measured by a thermal transistor are discussed below. For a thermal transistor implemented on a submicron process, such as the substrate PNP used on a Pentium III processor, the temperature errors due to the combined effect of the ideality factor and beta are shown to be less than 3C. Equation 2 is optimized for a substrate PNP transistor (used as a thermal diode) usually found on CPUs designed on submicron CMOS processes such as the Pentium III processor. There is a thermal diode on board each of these processors. The n in the Equation 2 represents the ideality factor of this thermal diode. This ideality factor is a measure of the deviation of the thermal diode from ideal behavior. According to Pentium III processor manufacturing specifications, measured values of n at 100C are: nMIN = 1.0057 < nTYPICAL = 1.008 < nMAX = 1.0125 The ADM1023 takes this ideality factor into consideration when calculating temperature TTD of the thermal diode. The ADM1023 is optimized for n TYPICAL = 1.008; any deviation on n from this typical value causes a temperature error that is calculated below for the nMIN and nMAX of a Pentium III processor at TTD = 100C,
DTMIN = 1.0057 - 1.008 1.008 (273.15 Kelvin + 100C ) = -0.85C
(2)
To measure VBE, the sensor is switched between operating currents of I and NI. The resulting waveform is passed through a low-pass filter to remove noise, then to a chopper-stabilized amplifier that performs the functions of amplification and rectification of the waveform to produce a dc voltage proportional to VBE. This voltage is measured by the ADC, which gives a temperature output in binary format. To further reduce the effects of noise, digital filtering is performed by averaging the results of 16 measurement -6-
DTMAX =
1.0125 - 1.008 1.008
(273.15 Kelvin + 100C ) = +1.67C
Thus, the temperature error due variation on n of the thermal diode for Pentium III processor is about 2.5C. REV. F
ADM1023
In general, this additional temperature error of the thermal diode measurement due to deviations on n from its typical value is given by,
DT = n - 1.008 (273.15 Kelvin + TTD ), where TTD is in C 1.008
The results of the local and remote temperature measurements are stored in the local and remote temperature value registers and are compared with limits programmed into the local and remote high and low limit registers.
Table II. Extended Temperature Resolution (Remote Temperature Low Byte)
BETA OF THERMAL TRANSISTOR ( )
In Figure 2, the thermal diode is a substrate PNP transistor where the emitter current is being forced into the device. The derivation of Equation 2 above assumed that the collector currents scaled by "N" as the emitter currents were also scaled by "N." In other words, this assumes that beta (b) of the transistor is constant for various collector currents. Figure 3 shows typical b variation versus collector current for Pentium III processors at 100C. The maximum b is 4.5 and varies less than 1% over the collector current range from 7 mA to 300 mA.
MAX
Extended Resolution ( C) 0.000 0.125 0.250 0.375 0.500 0.625 0.750 0.875
REGISTER FUNCTIONS
Remote Temperature Low Byte 0000 0000 0010 0000 0100 0000 0110 0000 1000 0000 1010 0000 1100 0000 1110 0000
< 4.5 IE
IC =
+1
IE
7
300
IC (mA)
Figure 3. Variation of b with Collector Currents
Expressing the collector current in terms of the emitter current, IC = IE [b/(b + 1)] where b(300 mA) = b(7 mA)(1 + e ), e = Db/b and b = b (7 mA). Rewriting the equation for DVBE, to include the ideality factor "n" and beta "b" we have,
DVBE E (1 + e ) (b + 1) nKT = 1n I N q I (1 + e ) b + 1
(3)
The ADM1023 contains registers that are used to store the results of remote and local temperature measurements, high and low temperature limits, and to configure and control the device. A description of these registers follows, and further details are given in Tables III to VII. It should be noted that most of the ADM1023's registers are dual port and have different addresses for read and write operations. Attempting to write to a read address, or to read from a write address, will produce an invalid result. Register addresses above 14h are reserved for future use or used for factory test purposes and should not be written to.
Address Pointer Register
b variations of less than 1% (e < 0.01) contribute to temperature errors of less than 0.4C.
TEMPERATURE DATA FORMAT
The Address Pointer Register itself does not have, nor does it require, an address, as it is the register to which the first data byte of every write operation is written automatically. This data byte is an address pointer that sets up one of the other registers for the second byte of the write operation, or for a subsequent read operation.
Value Registers
One LSB of the ADC corresponds to 0.125C, so the ADM1023 can measure from 0C to 127.875C. The temperature data format and extended temperature resolution are shown in Tables I and II.
Table I. Temperature Data Format (Local Temperature and Remote Temperature High Byte)
The ADM1023 has three registers to store the results of Local and Remote temperature measurements. These registers are written to by the ADC and can only be read over the SMBus.
The Offset Register
Temperature ( C)* 0 1 10 25 50 75 100 125 127
Digital Output 0 000 0000 0 000 0001 0 000 1010 0 001 1001 0 011 0010 0 100 1011 0 110 0100 0 111 1101 0 111 1111
Two offset registers are provided at addresses 11h and 12h. These are provided so that the user may remove errors from the measured values of remote temperature. These errors may be introduced by clock noise and PCB track resistance. Table IV contains a set of example offset values. The offset value is stored as an 11-bit, two's complement value in Registers 11h (high byte) and 12h (low byte, left-justified). The value of the offset is negative if the MSB of 11h is 1 and is positive if the MSB of 11h is 0. This value is added to the remote temperature. These registers default to zero at power-up and will have no effect if nothing is written to them. The offset register can accept values from -128.875C to +127.875C. The ADM1023 detects overflow so the remote temperature value register will not wrap around +127C or -128C.
*The ADM1023 differs from the ADM1021 in that the temperature resolution of the remote channel is improved from 1C to 0.125C, but it cannot measure temperatures below 0C. If negative temperature measurement is required, the ADM1021 should be used.
REV. F
-7-
ADM1023
Table III. List of ADM1023 Registers
READ Address (Hex) Not Applicable 00 01 02 03 04 05 06 07 08 Not Applicable 10 11 12 13 14 19 20 FE FF
WRITE Address (Hex) Not Applicable Not Applicable Not Applicable Not Applicable 09 0A 0B 0C 0D 0E 0F* Not Applicable 11 12 13 14 Not Applicable 21 Not Applicable Not Applicable
Name Address Pointer Local Temperature Value Remote Temperature Value High Byte Status Configuration Conversion Rate Local Temperature High Limit Local Temperature Low Limit Remote Temperature High Limit High Byte Remote Temperature Low Limit High Byte One-Shot Remote Temperature Value Low Byte Remote Temperature Offset High Byte Remote Temperature Offset Low Byte Remote Temperature High Limit Low Byte Remote Temperature Low Limit Low Byte Reserved Reserved Manufacturer Device ID Die Revision Code
Power-On Default Undefined 1000 0000 (80h) (-128C) 1000 0000 (80h) (-128C) Undefined 0000 0000 (00h) 0000 0010 (02h) 0111 1111 (7Fh) (+127C) 1100 1001 (C9h) (-55C) 0111 1111 (7Fh) (+127C) 1100 1001 (C9h) (-55C) 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 Undefined 0100 0001 (41h) 0011 xxxx (3xh)
*Writing to address 0F causes the ADM1023 to perform a single measurement. It is not a data register as such and it does not matter what data is written to it.
Table IV. Offset Values
Offset Registers 11h 12h
1111 1100 1111 1111 1111 1111 0000 0000 0000 0000 0000 0001 0000 0100
Offset Value
Remote Temperature (Including Offset)
14C 17C
Remote Temperature (Without Offset)
18C 18C 18C 18C 18C 18C 18C
be reset. A flag bit can only be reset if the corresponding value register contains an in-limit measurement, or the sensor is good. The ALERT interrupt latch is not reset by reading the Status Register, but will be reset when the ALERT output has been serviced by the master reading the device address, provided the error condition has gone away and the Status Register flag bits have been reset.
Table V. Status Register Bit Assignments
0000 0000 -4C 0000 0000 -1C
1110 0000 -0.125C 17.875C 0000 0000 0C 18C
Bit 7 6 5 4 3 2 1-0
Name BUSY LHIGH* LLOW* RHIGH* RLOW* OPEN*
Function 1 When ADC Converting 1 When Local High Temp Limit Tripped 1 When Local Low Temp Limit Tripped 1 When Remote High Temp Limit Tripped 1 When Remote Low Temp Limit Tripped 1 When Remote Sensor Open-Circuit Reserved
0010 0000 +0.125C 18.125C 0000 0000 +1C 0000 0000 +4C 19C 22C
Status Register
Bit 7 of the Status Register (see Table V) indicates that the ADC is busy converting when it is high. Bits 6 to 3 are flags that indicate the results of the limit comparisons. If the local and/or remote temperature measurement is above the corresponding high temperature limit, or below the corresponding low temperature limit, one or more of these flags will be set. Bit 2 is a flag that is set if the remote temperature sensor is open-circuit. These five flags are NOR'd together, so that if any of them are high, the ALERT interrupt latch will be set and the ALERT output will go low. Reading the Status Register will clear the five flag bits, provided the error conditions that caused the flags to be set have gone away. While a limit comparator is tripped due to a value register containing an out-of-limit measurement, or the sensor is open-circuit, the corresponding flag bit cannot
*These flags stay high until the status register is read or they are reset by POR.
Configuration Register
Two bits of the configuration register are used. If Bit 6 is 0, which is the power-on default, the device is in operating mode with the ADC converting (see Table VI). If Bit 6 is set to 1, the device is in standby mode and the ADC does not convert. Standby mode can also be selected by taking the STBY pin low. In standby mode the values of remote and local temperature remain at the value they were before the part was placed in standby. Bit 7 of the configuration register is used to mask the ALERT output. If Bit 7 is 0, which is the power-on default, the ALERT output is enabled. If Bit 7 is set to 1, the ALERT output is disabled.
-8-
REV. F
ADM1023
Table VI. Configuration Register Bit Assignments
Bit 7 6 5-0
Name MASK1 RUN/STOP
Function 0 = ALERT Enabled 1 = ALERT Masked 0 = Run 1 = Standby Reserved
Power-On Default 0 0 0
address pins, ADD0 and ADD1, to allow selection of the device address, so that several ADM1023s can be used on the same bus to avoid conflict with other devices. Although only two address pins are provided, these are three-state and can be grounded, left unconnected, or tied to VDD, so that a total of nine different addresses are possible, as shown in Table VIII. It should be noted that the state of the address pins is only sampled at power-up, so changing them after power-up will have no effect.
Table VIII. Device Addresses
Conversion Rate Register
The lowest three bits of this register are used to program the conversion rate by dividing the ADC clock by 1, 2, 4, 8, 16, 32, 64, or 128, to give conversion times from 125 ms (Code 07h) to 16 seconds (Code 00h). This register can be written to and read back over the SMBus. The higher five bits of this register are unused and must be set to zero. Use of slower conversion times greatly reduces the device power consumption, as shown in Table VII.
Table VII. Conversion Rate Register Codes
ADD0 0 0 0 NC NC NC 1 1 1
ADD1 0 NC 1 0 NC 1 0 NC 1
Device Address 0011 000 0011 001 0011 010 0101 001 0101 010 0101 011 1001 100 1001 101 1001 110
Data 00h 01h 02h 03h 04h 05h 06h 07h 08h to FFh
Conversion/Sec 0.0625 0.125 0.25 0.5 1 2 4 8 Reserved
Average Supply Current A Typ at VCC = 3.3 V 150 150 150 150 150 150 160 180
ADD0, ADD1 sampled at power-up only.
The serial bus protocol operates as follows: 1. The master initiates data transfer by establishing a START condition, defined as a high-to-low transition on the serial data line SDATA, while the serial clock line SCLK remains high. This indicates that an address/data stream will follow. All slave peripherals connected to the serial bus respond to the START condition and shift in the next 8 bits, consisting of a 7-bit address (MSB first) plus an R/W bit, which determines the direction of the data transfer, i.e., whether data will be written to or read from the slave device. The peripheral whose address corresponds to the transmitted address responds by pulling the data line low during the low period before the ninth clock pulse, known as the Acknowledge Bit. All other devices on the bus now remain idle while the selected device waits for data to be read from or written to it. If the R/W bit is a 0, the master will write to the slave device. If the R/W bit is a 1, the master will read from the slave device. 2. Data is sent over the serial bus in sequences of nine clock pulses, 8 bits of data followed by an acknowledge bit from the slave device. Transitions on the data line must occur during the low period of the clock signal and remain stable during the high period, as a low-to-high transition when the clock is high may be interpreted as a STOP signal. The number of data bytes that can be transmitted over the serial bus in a single READ or WRITE operation is limited only by what the master and slave devices can handle. 3. When all data bytes have been read or written, stop conditions are established. In WRITE mode, the master will pull the data line high during the 10th clock pulse to assert a STOP condition. In READ mode, the master device will override the acknowledge bit by pulling the data line high during the low period before the ninth clock pulse. This is known as No Acknowledge. The master will then take the data line low during the low period before the 10th clock pulse, then high during the 10th clock pulse to assert a STOP condition. Any number of bytes of data may be transferred over the serial bus in one operation, but it is not possible to mix read and write in -9-
Limit Registers
The ADM1023 has six limit registers to store local and remote, high and low temperature limits. These registers can be written to and read back, over the SMBus. The high limit registers perform a > comparison while the low limit registers perform a < comparison. For example, if the high limit register is programmed as a limit of 80C, measuring 81C will result in an alarm condition. Even though the temperature range is 0 to 127C, it is possible to program the Limit Register with negative values. This is for backwards-compatibility with the ADM1021.
One-Shot Register
The one-shot register is used to initiate a single conversion and comparison cycle when the ADM1023 is in standby mode, after which the device returns to standby. This is not a data register as such and it is the write operation that causes the one-shot conversion. The data written to this address is irrelevant and is not stored.
SERIAL BUS INTERFACE
Control of the ADM1023 is carried out via the serial bus. The ADM1023 is connected to this bus as a slave device, under the control of a master device. Note that the SMBus SDA and SCL pins are three-stated when the ADM1023 is powered down and will not pull down the SMBus.
ADDRESS PINS
In general, every SMBus device has a 7-bit device address (except for some devices that have extended, 10-bit addresses). When the master device sends a device address over the bus, the slave device with that address will respond. The ADM1023 has two REV. F
ADM1023
1 SCLK 9 1 9
SDATA START BY MASTER
0
1
0
1
1
A1
A0
R/W ACK. BY ADM1023
D7
D6
D5
D4
D3
D2
D1
D0 ACK. BY ADM1023
FRAME 1 SERIAL BUS ADDRESS BYTE 1 SCLK (CONTINUED)
FRAME 2 ADDRESS POINTER REGISTER BYTE 9
SDATA (CONTINUED)
D7
D6
D5
D4
D3
D2
D1
D0 ACK. BY STOP BY ADM1023 MASTER
FRAME 3 DATA BYTE
Figure 4. Writing a Register Address to the Address Pointer Register, then Writing Data to the Selected Register
1 SCLK 9 1 9
SDATA START BY MASTER
0
1
0
1
1
A1
A0
R/W ACK. BY ADM1023
D7
D6
D5
D4
D3
D2
D1
D0 ACK. BY ADM1023 STOP BY MASTER
FRAME 1 SERIAL BUS ADDRESS BYTE
FRAME 2 ADDRESS POINTER REGISTER BYTE
Figure 5. Writing to the Address Pointer Register Only
1 SCLK 9 1 9
SDATA START BY MASTER
A6
A5
A4
A3
A2
A1
A0
R/W ACK. BY ADM1023
D7
D6
D5
D4
D3
D2
D1
D0 NO ACK. BY MASTER STOP BY MASTER
FRAME 1 SERIAL BUS ADDRESS BYTE
FRAME 2 DATA BYTE FROM ADM1023
Figure 6. Reading Data from a Previously Selected Register
one operation, because the type of operation is determined at the beginning and cannot subsequently be changed without starting a new operation. In the case of the ADM1023, write operations contain either one or two bytes, while read operations contain one byte and perform the following functions: To write data to one of the device data registers, or read data from it, the Address Pointer Register must be set so that the correct data register is addressed. Data can then be written into that register or read from it. The first byte of a write operation always contains a valid address that is stored in the Address Pointer Register. If data is to be written to the device, the write operation contains a second data byte that is written to the register selected by the address pointer register. This is illustrated in Figure 4. The device address is sent over the bus followed by R/W set to 0. This is followed by two data bytes. The first data byte is the address of the internal data register to be written to, which is stored in the Address Pointer Register. The second data byte is the data to be written to the internal data register.
When reading data from a register there are two possibilities: 1. If the ADM1023's Address Pointer Register value is unknown, or not the desired value, it is first necessary to set it to the correct value before data can be read from the desired data register. This is done by performing a write to the ADM1023 as before, but only the data byte containing the register read address is sent, as data is not to be written to the register. This is shown in Figure 5. A read operation is then performed consisting of the serial bus address, R/W bit set to 1, followed by the data byte read from the data register. This is shown in Figure 6. 2. If the Address Pointer Register is known to be at the desired address already, data can be read from the corresponding data register without first writing to the Address Pointer Register. NOTES 1. Although it is possible to read a data byte from a data register without first writing to the Address Pointer Register, if the Address Pointer Register is already at the correct value, it is not possible to write data to a register without writing to the
-10-
REV. F
ADM1023
Address Pointer Register, because the first data byte of a write is always written to the Address Pointer Register. 2. Do not forget that ADM1023 registers have different addresses for read and write operations. The write address of a register must be written to the Address Pointer if data is to be written to that register, but it is not possible to read data from that address. The read address of a register must be written to the Address Pointer before data can be read from that register.
ALERT OUTPUT
The SMBus is still enabled. Power consumption in the standby mode is reduced to less than 10 mA if there is no SMBus activity, or 100 mA if there are clock and data signals on the bus. These two modes are similar but not identical. When STBY is low, conversions are completely inhibited. When Bit 6 is set but STBY is high, a one-shot conversion of both channels can be initiated by writing any data value to the One-Shot Register (Address 0Fh).
SENSOR FAULT DETECTION
The ALERT output goes low whenever an out-of-limit measurement is detected, or if the remote temperature sensor is open-circuit. It is an open drain and requires a 10 kW pull-up to VDD. Several ALERT outputs can be wire-ANDED together, so that the common line will go low if one or more of the ALERT outputs goes low. The ALERT output can be used as an interrupt signal to a processor, or it may be used as an SMBALERT. Slave devices on the SMBus normally cannot signal to the master that they want to talk, but the SMBALERT function allows them to do so. One or more ALERT outputs are connected to a common SMBALERT line connected to the master. When the SMBALERT line is pulled low by one of the devices, the following procedure occurs as illustrated in Figure 7.
MASTER RECEIVES SMBALERT START ALERT RESPONSE ADDRESS MASTER SENDS ARA AND READ COMMAND RD ACK DEVICE ADDRESS NO ACK STOP
The ADM1023 has a fault detector at the D+ input that detects if the external sensor diode is open-circuit. This is a simple voltage comparator that trips if the voltage at D+ exceeds VCC - 1 V (typical). The output of this comparator is checked when a conversion is initiated and sets Bit 2 of the Status Register if a fault is detected. If the remote sensor voltage falls below the normal measuring range, for example, due to the diode being short-circuited, the ADC will output -128C (1000 0000 000). Since the normal operating temperature range of the device only extends down to 0C, this output code will never be seen in normal operation, so it can be interpreted as a fault condition. In this respect, the ADM1023 differs from and improves upon competitive devices that output zero if the external sensor goes short-circuit. These devices can misinterpret a genuine 0C measurement as a fault condition. If the external diode channel is not being used and is shorted out, the resulting ALERT may be cleared by writing 80h (-128C) to the low limit register.
APPLICATIONS INFORMATION FACTORS AFFECTING ACCURACY Remote Sensing Diode
DEVICE SENDS ITS ADDRESS
Figure 7. Use of SMBALERT
1. SMBALERT pulled low. 2. Master initiates a read operation and sends the Alert Response Address (ARA = 0001 100). This is a general call address that must not be used as a specific device address. 3. The device whose ALERT output is low responds to the Alert Response Address and the master reads its device address. The address of the device is now known and it can be interrogated in the usual way. 4. If more than one device's ALERT output is low, the one with the lowest device address will have priority, in accordance with normal SMBus arbitration. 5. Once the ADM1023 has responded to the Alert Response Address, it will reset its ALERT output, provided that the error condition that caused the ALERT no longer exists. If the SMBALERT line remains low, the master will send ARA again, and so on until all devices whose ALERT outputs were low have responded.
LOW POWER STANDBY MODES
The ADM1023 is designed to work with substrate transistors built into processors, or with discrete transistors. Substrate transistors will generally be PNP types with the collector connected to the substrate. Discrete types can be either PNP or NPN, connected as a diode (base shorted to collector). If an NPN transistor is used then the collector and base are connected to D+ and the emitter to D-. If a PNP transistor is used, the collector and base are connected to D- and the emitter to D+. The user has no choice in the case of substrate transistors, but if a discrete transistor is used, the best accuracy will be achieved by choosing devices according to the following criteria: 1. Base emitter voltage greater than 0.25 V at 6 mA, at the highest operating temperature. 2. Base emitter voltage less than 0.95 V at 100 mA, at the lowest operating temperature. 3. Base resistance less than 100 W. 4. Small variation in hfe (say 50 to 150), which indicates tight control of VBE characteristics. Transistors such as 2N3904, 2N3906, or equivalents in SOT-23 package are suitable devices to use.
Thermal Inertia and Self-Heating
The ADM1023 can be put into a low power standby mode using hardware or software, that is, by taking the STBY input low, or by setting Bit 6 of the Configuration Register. When STBY is high or Bit 6 is low, the ADM1023 operates normally. When STBY is pulled low or Bit 6 is high, the ADC is inhibited, and any conversion in progress is terminated without writing the result to the corresponding value register. REV. F
Accuracy depends on the temperature of the remote-sensing diode and/or the internal temperature sensor being at the same temperature as that being measured; and a number of factors can affect this. Ideally, the sensor should be in good thermal -11-
ADM1023
contact with the part of the system being measured, such as the processor, for example. If it is not, the thermal inertia caused by the mass of the sensor will cause a lag in the response of the sensor to a temperature change. In the case of the remote sensor this should not be a problem, as it will be either a substrate transistor in the processor or a small package device such as SOT-23 placed in close proximity to it. The on-chip sensor, however, will often be remote from the processor and will only be monitoring the general ambient temperature around the package. The thermal time constant of the QSOP-16 package is about 10 seconds. In practice, the package will have electrical, and hence thermal, connection to the printed circuit board, so the temperature rise due to self-heating will be negligible.
LAYOUT CONSIDERATIONS
7. For really long distances (up to 100 feet), use shielded twisted pair such as Belden #8451 microphone cable. Connect the twisted pair to D+ and D- and the shield to GND close to the ADM1023. Leave the remote end of the shield unconnected to avoid ground loops. Because the measurement technique uses switched current sources, excessive cable and/or filter capacitance can affect the measurement. When using long cables, the filter capacitor may be reduced or removed. Cable resistance can also introduce errors. 1 W series resistance introduces about 1C error.
APPLICATION CIRCUITS
Digital boards can be electrically noisy environments, and the ADM1023 is measuring very small voltages from the remote sensor, so care must be taken to minimize noise induced at the sensor inputs. The following precautions should be taken: 1. Place the ADM1023 as close as possible to the remote sensing diode. Provided that the worst noise sources, such as clock generators, data/address buses, and CRTs, are avoided, this distance can be four to eight inches. 2. Route the D+ and D- tracks close together, in parallel, with grounded guard tracks on each side. Provide a ground plane under the tracks if possible (Figure 8). 3. Use wide tracks to minimize inductance and reduce noise pickup. 10 mil track minimum width and spacing is recommended.
GND 10MIL 10MIL D+ 10MIL 10MIL
Figure 9 shows a typical application circuit for the ADM1023, using a discrete sensor transistor connected via a shielded, twisted pair cable. The pull-ups on SCLK, SDATA, and ALERT are required only if they are not already provided elsewhere in the system.
0.1 F VDD 3V TO 5.5V 10k 10k 10k IN I/O OUT SET TO REQUIRED ADDRESS TO CONTROL CHIP
ADM1023
D+ 2200pF D- 2N3904 SHIELD SDATA ALERT ADD0 ADD1 GND SCLK
Figure 9. Typical Application Circuit
The SCLK and SDATA pins of the ADM1023 can be interfaced directly to the SMBus of an I/O chip. Figure 10 shows how the ADM1023 might be integrated into a system using this type of I/O controller.
D-
D-
10MIL 10MIL
PROCESSOR
D+
ADM1023
ALERT SDATA
GND
10MIL
Figure 8. Arrangement of Signal Tracks
SYSTEM BUS DISPLAY DISPLAY CACHE CD ROM HARD DISK ICH I/O CONTROLLER HUB GMCH SYSTEM MEMORY PCI SLOTS
4. Try to minimize the number of copper/solder joints, which can cause thermocouple effects. Where copper/solder joints are used, make sure that they are in both the D+ and D- path and at the same temperature. Thermocouple effects should not be a major problem as 1C corresponds to about 240 mV, and thermocouple voltages are about 3 mV/C of temperature difference. Unless there are two thermocouples with a big temperature differential between them, thermocouple voltages should be much less than 240 mV. 5. Place a 0.1 mF bypass capacitor close to the VDD pin and 2200 pF input filter capacitors across D+, D- close to the ADM1023. 6. If the distance to the remote sensor is more than eight inches, the use of twisted pair cable is recommended. This will work up to approximately 6 to 12 feet.
PCI BUS SUPER I/O SMBUS
2 IDE PORTS USB USB 2 USB PORTS
FWH (FIRMWARE HUB)
Figure 10. System Using ADM1023 and I/O Controller
-12-
SCLK
REV. F
ADM1023
OUTLINE DIMENSIONS 16-Lead Shrink Small Outline Package [QSOP] (RQ-16)
Dimensions shown in inches
0.193 BSC
16
9
0.154 BSC
1 8
0.236 BSC
PIN 1 0.065 0.049 0.069 0.053
0.010 0.025 0.004 BSC COPLANARITY 0.004
0.012 0.008
SEATING PLANE
0.010 0.006
8 0
0.050 0.016
COMPLIANT TO JEDEC STANDARDS MO-137AB
REV. F
-13-
ADM1023 Revision History
Location 4/03--Data Sheet changed from REV. E to REV. F. Page
Added Reference to Figure 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
4/03--Data Sheet changed from REV. D to REV. E.
Added ESD Caution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Updated OUTLINE DIMENSIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
9/02--Data Sheet changed from REV. C to REV. D.
OUTLINE DIMENSIONS updated . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
5/02--Data Sheet changed from REV. B to REV. C.
Figures 2 to 11 changed to TPCs 1-10, renumbered remaining figures accordingly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Text change to Figure 9 (TPC 8) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Callouts in text added for Tables IV-VI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Change to SERIAL BUS INTERFACE section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
-14-
REV. F
-15-
-16-
C00058-0-4/03(F)


▲Up To Search▲   

 
Price & Availability of ADM1023ARQ-REEL

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X